| Code | Text | Type | Applies to | products affected | |
|---|---|---|---|---|---|
| ST1212 | Wear particle-filtering half mask FFP2 or half mask with particle filter P2 (identification colour: white) according to the BVL guideline "Personal protective equipment for handling plant protection products", current version, when applying/handling the product ready for application in closed rooms. | Condition of use | Product | 1 | Products carrying this text |
| ST132 | A particle-filtering half mask FFP2 or half mask with particle filter P2 (identification colour: white) according to the BVL guideline "Personal protective equipment for handling plant protection products", current version, must be worn when filling or decanting the product and when cleaning the application device. | Condition of use | Product | 1 | Products carrying this text |
| ST2202 | Wear half mask with combination filter A1-P2 (identification colour: brown/white) according to the BVL guideline "Personal protective equipment for handling plant protection products", current version, when applying/handling the product ready for application. | Restriction | Product | 1 | Products carrying this text |
| ST227 | Wear half mask with combination filter A1-P2 (identification colour: brown/white) according to the BVL guideline "Personal protective equipment for handling plant protection products", current version, when applying/handling the product as well as during follow-up work during the day of application. | Condition of use | Product | 1 | Products carrying this text |
| ST303 | Do not inhale dust. | Restriction | Product | 1 | Products carrying this text |
| ST340 | While filling manually the application device a full-face mask with combination filter A1-P3 (identification colour: brown/white) according to the BVL guideline "Personal protective equipment for handling plant protection products", current version, must be worn. | Condition of use | Product | 1 | Products carrying this text |
| ST5001 | Wear respiratory equipment which does not rely on recirculated air when applying/handling the product. | Condition of use | Product | 1 | Products carrying this text |
| VA212 | Users are not allowed to treat more than a total of 135 tons of potatoes per working day. | Restriction | Product | 1 | Products carrying this text |
| VA212-1 | Users are not allowed to treat more than a total of 100 tons of potatoes per working day. | Restriction | Product | 1 | Products carrying this text |
| VA233 | Cereals stored in mills must be put in gas proof packaging prior to treatment. | Restriction | Use | 1 | Products carrying this text |
| VA234 | Silos and pipe systems which are not gas-proof must be emptied completely prior to treatment. | Restriction | Use | 1 | Products carrying this text |
| VA235 | Products from cereals where exposure cannot be avoided for technical reasons are not allowed to reach the food and feed chain. | Restriction | Use | 1 | Products carrying this text |
| VA236 | The presence of cereal products and milled or decorticated mill products during treatment must be excluded. | Restriction | Use | 1 | Products carrying this text |
| VA244 | Storage products must not be treated at the same time. | Restriction | Use | 1 | Products carrying this text |
| VA269-1 | In field crops the product must be applied using loss reducing equipment which is registered in the index of 'Loss Reducing Equipment' of 14 October 1993 (Federal Gazette No 205, p. 9780) as amended, and be registered in at least drift reducing class 50 %. | Condition of use | Product | 1 | Products carrying this text |
| VA272 | The first ventilation of the storage facility after treatment shall be carried out when the wind speed is greater than 2 m/s. | Restriction | Product | 1 | Products carrying this text |
| VA273-1 | In the case of termination of plantation before harvest, it must be ensured that crops which are used for the production of food and fodder are seeded/replanted at the earliest 4 month after the application. | Condition of use | Product | 1 | Products carrying this text |
| VA278 | The storage treatment may only take place if the ventilation openings of the storage building are at a height of at least 5 m. | Condition of use | Product | 1 | Products carrying this text |
| VA279 | In order to protect bystanders, when applying the product a strip at least 10 m wide adjacent to other areas must be applied with loss reducing equipment which is registered in the index of 'Loss Reducing Equipment' of 14 October 1993 (Federal Gazette No 205, p. 9780) as amended, and is registered in at least drift reducing class 90%. | Condition of use | Use | 1 | Products carrying this text |
| VA281 | When using the product, a buffer zone of 10 m must be kept next to adjacent areas used by uninvolved third parties. The product must be applied using loss reducing equipment which is registered in the index of 'Loss Reducing Equipment' of 14 October 1993 (Federal Gazette No 205, p. 9780) as amended, and be registered in at least drift reducing class 50 %. | Condition of use | Product | 1 | Products carrying this text |
| VA282 | In order to protect uninvolved third parties (bystanders and residents), the Plant Protection Product must be applied with loss reducing equipment which is registered in the index of 'Loss Reducing Equipment' of 10 September 1993 (Federal Gazette AT 23.10.2013 B4) as amended, and is registered in at least drift reducing class 90%. | Condition of use | Product | 1 | Products carrying this text |
| VA290 | In case of crop failure, it must be ensured that no root vegetables (except sugar beet and fodder beet) are seeded/replanted. | Restriction | Product | 1 | Products carrying this text |
| VA310 | Only totally impermeable films with a transmission rate lower than 10 mg per square metre per hour may be used for covering treated soils. | Condition of use | Product | 1 | Products carrying this text |
| VA311 | Use only on a soil with a soil humidity with a binding capacity of 60-70%. | Condition of use | Product | 1 | Products carrying this text |
| VA312 | It must be ensured that the soil will be covered with a gastight TIFFfoil (totally impermeable film) for at least 5 weeks after application. | Condition of use | Product | 1 | Products carrying this text |